L.C. Switchgear Ltd |
|
Specialists in Switchgear Design & Manufacture |

|
To contact us: mail@lcswitchgear.com |
|
Phone: 00 44 (0)1273 770540 Fax: 00 44 (0)1273 770547 E-mail: mail@lcswitchgear.com |
|
Industrial Isolator - 1000V AC, 40A to 1600A
Multi-pole construction 2, 3 or 4 pole standard, On Load Disconnector Visible breaking contacts (through window). High speed mechanism Silver plated copper contacts. Breaking chambers on all poles made from GRP (UL 94 VO) High make and break capacity (AC23 & DC23 rating) |

|
Heavy Duty Industrial Isolator - 1000V AC/DC 500A
3 pole Off Load Disconnector · Visible breaking contacts (through window). · Silver plated copper contacts · Left hand side operation · Wall Mounting · Cases with a degree of protection to IP 547 · Heavy Duty Continuously Welded Construction · Padlocking handle · Bottom cable entry |






|
Isolator & Earthing Changeover Switch - 1000V AC 400A
Single Pole Silver plated copper contacts Right hand side operation Wall Mounting Degree of protection to IP 54 Padlocking handle Top and bottom cable entry |
|
4 Pole Changeover Isolator - 750V AC 1000A
4 pole construction. Silver plated copper contacts Right hand side operation Floor standing Degree of protection to IP 54 Padlocking handle Top & Bottom cable entry |
|
Medium Voltage Isolator – 3.3kV 300A Isolation of Medium Voltage motor / transformer supplies, 3.3kV, for maintenance. C79 Off-Load 350A 3 Pole Disconnector off load switch. Features · IP54 · Top cable entry for 3ph armoured cables. · Manual handle / isolator door interlocks. · Auxiliary switch terminals accessible at the top of the panel. |
|
4 Pole Isolating and Earthing Unit - 415V AC 250A
Isolating and Earthing Unit for a nuclear research centre Magnet power supply. Consisting of an on-load Contactor, a motorised off-load Disconnector, fuses and a control circuit. Isolation of medium voltage magnet supplies, 3.3kV, for maintenance. |
|
2 Pole Earthing Changeover Switch Panel (twin isolators)
250V DC supply is derived from the Magnet Power Supply. The 250V DC is fed to the respective 2 pole disconnector, via 2 x 150mm2 cables coming in from the base of the enclosure When the Disconnector is moved to the earthed position the outgoing supplies to the respective magnet are earthed and can be interlocked, making them safe for maintenance. Tool operated doors prevent access to sections containing 250V DC |
|
MV TIL & TIR - Medium Voltage Twin Isolator Left & Right Hand – 430A 3.3 to 12kV
Isolation of Medium Voltage motor / transformer supplies, 3.3kV to 12kV, for maintenance. Two MV(1-0) manual isolators on load. Features · IP56 · Separate motor / transformer isolator bays, with top cable entry for 3ph armoured cables. · Manual handle / isolator door interlocks. · Auxiliary switch terminals accessible at the top of the panel. |