LCS2 Supply Disconnector
4000A 750V DC (TIS / TD) - Network Rail No PA05/454 Off-load distribution of power from substations and track isolation
LCS2-2 Pole 2000A version is also available. |

|
Feeder Bypass Isolators & Feeder Isolators 2000A 750V DC Substation feed selection and switching of high power circuits. Substation feed selection and Isolation / Earthing and/or switching of high power circuits Used on Dockland Light Railway. |




|
Section Switches Motorised & Manual 2000A 750V DC Off-load Isolation / Earthing and / or switching of high power circuits, where a high short circuit withstand and high voltage isolation is required. Used on Croydon Tramway, where the switches ensure safe track working conditions |
|
Tunnel Section Switches Motorised (Remote Controlled) & Manual 4000A 630V DC Off-load / fault make track section isolation of high power circuits, where a high short circuit withstand and high voltage isolation is required. Used on London Underground, where the switches ensure safe track working conditions |
|
Surface Track Section Switches Motorised 4000A 630V DC
On-load track section switching of high power circuits, where a high short circuit withstand and high voltage isolation is required. Used on London Underground, where the switches ensure safe track working conditions |
|
CTS Controlled Track Isolating Switch MK 2 2000/4000A 750V DC Network Rail No PA05/02035
On-load switching of high power circuits with off load Isolation for switch maintenance, where a high short circuit withstand and high voltage isolation is required. Used on Network Rail.
|
|
Link boxes & Link Boxes with Motorised Bypass 2000/3600A 1500V DC
Off-load un-bolt able Isolation links and motorised bypass switching of high power circuits. Various configurations of links available without the bypass switch.
|
|
Spark Gap & Non Linear Resistor Cubicles – 2000A/4000A/6000A/8000A or 9000A rms for 0.2s Where there is 25kV overhead lines and 750V DC, the non-linear resistors provide a path back to source for currents flowing in short circuits of the 25kV AC overhead lines, while limiting the current which flows during the normal operation of the railway. The spark gap device triggers to limit earth voltage to a safe level. The resistors limit the running rail touch voltage to within safe levels. This restricts the risk of stray DC currents. Note some units have been supplied without the spark gap device where the detection has been provided externally to the resistor panel. |