Depot 1 & 2 Pole DCP Depot Road Contactor Panels 1kA and 2kA 750V DC
L.C. SWITCHGEAR LTD.
+44 (0)1273 770540

Depot 1 & 2 Pole DCP Depot Road Contactor Panels 1kA and 2kA 750V DC

Product Image

DCP – 1 Pole Depot Contactor Panels – 1kA 750V DC

8800262

Application – on load

1 pole changeover switching of high power circuits, where a high short circuit withstand and high voltage isolation is required.

Road isolation in Southern Depots

Switches and Contactor

Contactors 1000A with Negative Bonding Contact

Incoming Disconnector 1250A

Features

IP55

1000A Traction Grade Fuse

DC Overload Protection

Anti-Condensation Heaters

Anti-Condensation Paint

Installation

Floor mounted

Cable entry from below via insulating gland plates

Cabling

Incoming Positive 1 x 1000mm2 Aluminium

Outgoing Positive 1 x 1000mm2 Aluminium

Incoming Negative 2 x 250mm2

Earth 1 x 250mm2

 

8800262

Voltage 750V DC

Current 1kA

Length 1500 mm

Height 2200 mm

Depth 850 mm

Weight 450kg

 

DCP – 2 Pole Depot Contactor Panel – 1kA 750V DC

8800260 & 8800265

Application – on load

2 pole changeover switching of high power circuits, where a high short circuit withstand and high voltage isolation is required.

Road isolation in Southern Depots

Switches and Contactor

1000A 2 Pole Contactor

2000A Incoming Disconnector

1250A Outgoing Bonding Switch

Features

IP55

1000A Traction Grade Fuse

DC Overload Protection

Anti-Condensation Heaters

Anti-Condensation Paint

Installation

Floor mounted

8800260 - Cable entry from below via insulating gland plates

8800265 – Cable entry from the rear via split insulating plates

Cabling

Incoming Positive 2 x 1000mm2 Aluminium

Outgoing Positive 1# 2 x 185mm2

Outgoing Positive 2# 1 x 1000mm2 Aluminium

Incoming Negative 2 x 250mm2

Earth 1 x 250mm2

8800260 8800265

Voltage 750V DC

Current 1kA

Length 1500 mm

Height 2200 mm

Depth 850 mm

Weight 450kg

 

 

DCP – 1 Pole Depot Contactor Panel 2kA 750V DC with Motor Driven Bonding Device

8800261

Application – on load

1 pole changeover switching of high power circuits, where a high short circuit withstand and high voltage isolation is required.

Road isolation and bonding in Southeastern Depots & Ramsgate Depot.

Switches and Contactor

Contactors 1 Pole 2000A with 1600A Motor Driven Negative Bonding Switch

Incoming Disconnector 2000A

Features

IP55

2000A Traction Grade Fuse

DC Overload Protection

Anti-Condensation Heaters

Anti-Condensation Paint

Installation

Floor mounted cable entry from below via insulating gland plates.

Cabling

Incoming Positive 4 x 1000mm2 Aluminium

Outgoing Positive 2 x 1000mm2 Aluminium

Incoming Negative 2 x 250mm2

Earth 1 x 250mm2

 

8800261 Bonding Devices

Voltage 750V DC 858961 & 863118

Current 2kA See Below

Length 1500 mm

Height 2705 mm

Depth 850 mm

Weight 470kg (688kg with Bonding Device)

 

BD – 1 Pole Contactor Panel Motor Driven Bonding Disconnector 1.6kA - Network Rail PA05/02927

Application – off load / fault make

The motor driven switch is to be used to bond the 750 Volt positive track feed connection to the negative rail and is electrically interlocked with its associated Contactor from which it obtains its control supply. Opening of the Contactor will cause the bonding device to close. The device is operated from the Contactor control circuit or automatically following the loss of the emergency circuit i.e. Emergency stop button activated.

Switch

(1-0) 1 pole motorised Off Load / Fault make Switch

Features

IP56

Protected for external use

Fully Isolated 110V AC Control Supply (Fed from the Contactor)

Anti Condensation Paint

Installation

Mounted directly on to contactor panel, bus bar connection via insulating gland plates

Electrical Characteristics & Dimensions

858961 863118 *

Voltage 750V DC

Current 1.6kA

Maximum Fault levels 85kA 150ms

70kA 250ms

Weight 135kg 158kg

Length 1500 mm

Height 500 mm

Depth 750 mm

* This version allows the bonding device and Contactor to be lifted in a single lift i.e. it includes additional structural components in the sheet metal design. The 858961 version needs to be fitted after the contactor is installed

 

DCP – 1 Pole Changeover Depot Contactor Panel - 1000A 750V DC

8800264

Application – on load

2 pole changeover switching of high power circuits, where a high short circuit withstand and high voltage isolation is required.

Road isolation and bonding in Southern Depots

Switches and Contactor

1000A Contactor with Negative Bonding Contact

1250A Incoming Disconnector

1250A Changeover & Bonding Isolator

Features

IP55

1000A Traction Grade Fused

DC Overload Protection

Anti Condensation Heaters

Anti Condensation Paint

Installation

Floor mounted, cable entry from the rear via split insulating plates

Cabling

Incoming Positive 2 x 1000mm2 Aluminium

Outgoing Positive 1# 2 x 185mm2

Outgoing Positive 2# 1 x 1000mm2 Aluminium

Negative 2 x 250mm2

Earth 1 x 250mm2

8800264

Voltage 750V

Current 1kA

Length 1500 mm

Height 2200 mm

Depth 850 mm

Weight 450kg

 

DCP – 1 Pole Depot Contactor Panel 1000A 750V DC

8800386

Application – on load

1 pole switching of high power circuits, where a high short circuit withstand and high voltage isolation is required.

Road isolation and bonding in Southern Depot at Selhurst

Switches and Contactor

Contactor 1 Pole 1000A 1kV

Incoming 1 pole Manual Disconnector 2000A 1.5kV

Outgoing 1 pole Manual Bonding Disconnector 1250A 1.5kV

Features

IP55

1000A 1kV Traction Grade Fuse

1600A DC Overload Protection

Anti Condensation Heaters

Anti Condensation Paint

Installation

Floor mounted, cable entry from below via insulating gland plates

Cabling

Incoming Positive 2 x 1000mm2 Aluminium

Outgoing Positive 2 x 185mm2

Incoming Negative 2 x 240mm2

Earth 2 x 240mm2

 

8800386

Voltage 750V

Current 1kA

Length 1500 mm

Height 2705 mm

Depth 850 mm

Weight 460kg

 

DRC – 1 Pole Train Wash Contactor Panel - 1000A 600V DC

SPT - STRATHCLYDE PASSENGER TRANSPORT

8800413

APPLICATION – ON LOAD

1 pole changeover switching of high power circuits, where a high short circuit withstand and high voltage isolation is required.

Train Wash Road isolation in Glasgow Metro Depot

Switches and Contactor

Contactors 1000A

Incoming Disconnector 1250A

Features

IP55

1000A Traction Grade Fuse

Anti Condensation Heaters

Anti Condensation Paint

Installation

Floor mounted

Cable entry from below via insulating gland plates

Cabling

Incoming Positive 1 x 1000mm2 Aluminium

Outgoing Positive 1 x 1000mm2 Aluminium

Incoming Negative 2 x 250mm2

Earth 1 x 250mm2

 

8800413

Voltage 600V

Current 1kA

Length 1500 mm

Height 2200 mm

Depth 850 mm

Weight 450kg

 

 

< Back to Railway Products & events